Cationic Polyacrylamide CPAM 0.05% Max Residual Monomer for Petrochemical Sludge Dewatering CAS 9003-05-8 ISO 9001 Manufacturer 25kg Kraft Paper Bag
Product Overview
In petrochemical wastewater treatment, polymer purchasing should begin with the real separation problem rather than a generic request for PAM. This page addresses oily, biological or physicochemical sludge containing hydrocarbons, catalyst fines and treatment precipitates. The objective is to create a floc that matches the hydraulic loading, shear and drainage mechanism of the centrifuge, filter press, belt press or screw press.

Sludge Dewatering Problem
The relevant feed is oily, biological or physicochemical sludge containing hydrocarbons, catalyst fines and treatment precipitates. The main operating difficulty is that hydrocarbon-coated particles, surfactants and variable process contaminants can prevent normal charge neutralization and drainage.
⚙️ How CPAM Supports the Separation Process
- Particle contact: The prepared CPAM solution disperses through the conditioned sludge.
- Charge response: The selected charge level reduces electrostatic stability.
- Polymer bridging: Extended chains connect multiple particles into floc.
- Equipment separation: Gravity, pressure or centrifugal separation.
- Controlled optimization: Dose, mixing energy and injection point adjustment.
Recommended Addition Point and Equipment Fit
Introduce the fully activated polymer at the following location: after oil separation, emulsion breaking and sludge equalization, before dewatering. The point must provide uniform contact without exposing newly formed floc to unnecessary high shear.
Grade Selection Guidance
BLUFLOC CPAM is available across a 5-12 million molecular-weight range and 5-80% charge-degree range.
- Test fresh, representative sludge at the normal feed-solids concentration.
- Keep upstream chemistry and mechanical settings constant during each comparison.
- Compare at least three doses for each candidate grade.
BLUFLOC Powder PAM Typical Supply Range
| Property | Specified Range | Practical Relevance |
|---|---|---|
| Appearance | Off-white granular powder | Dry, free-flowing product |
| Ionic type | Cationic | Select by sludge surface chemistry |
| Molecular weight | 5-12 million | Screen for floc size/shear |
| Charge range | 5-80% charge degree | Match sludge charge demand |
Polymer Solution Preparation
- Fill a clean make-down tank with suitable water and start moderate agitation.
- Meter the dry powder slowly and evenly into the moving water.
- Prepare a 0.1-0.5% solution.
- Agitate at approximately 200-400 rpm for about one hour.
Bench Test and Equipment Trial
- Collect the sludge during representative petrochemical wastewater treatment operation.
- Prepare fresh CPAM solutions at a known concentration.
- Run a dose-response series with equal mixing.
Operating Performance Indicators
| Indicator | Description |
|---|---|
| Solids capture | Measures particle retention. |
| Cake solids | Mass and transport impact. |
| Liquid quality | Track suspended solids/FOG. |
| Specific polymer use | Active polymer vs dry solids. |
Troubleshooting
| Issue | Action |
|---|---|
| Small or weak floc | Verify dissolution and charge. |
| Cloudy filtrate | Check underdosing and shear. |
| Sticky sludge | Reduce dose, improve dilution. |
Why Source BLUFLOC PAM from Bluwat Chemicals
- Anionic, cationic and nonionic powder ranges.
- Technical discussion based on sludge source.
- Jar-test samples available for evaluation.
- Export experience serving multiple markets.
Frequently Asked Questions
Is CPAM always the correct polymer?
No. Comparative testing is required to determine the best ionic type.
Can PAM solve poor precipitation or emulsion breaking?
No. Complete those upstream reactions first.
Request a Sludge Dewatering Evaluation
Send Bluwat Chemicals the sludge source, daily wet-sludge flow, feed-solids concentration, current polymer and dose, and other operating details to receive a tailored trial plan.