request to quote
Leave Your Message
Cationic Polyacrylamide CPAM 2-Year Shelf Life 89% Min Solid for Sewage Sludge Screw Press Dewatering CAS 9003-05-8 ISO 9001 Manufacturer 25kg PE Bag
Polyacrylamide for Sludge Dewatering
Products Categories
Featured Products

Cationic Polyacrylamide CPAM 2-Year Shelf Life 89% Min Solid for Sewage Sludge Screw Press Dewatering CAS 9003-05-8 ISO 9001 Manufacturer 25kg PE Bag

BLUFLOC Cationic Polyacrylamide (CPAM) is an off-white, water-soluble granular powder used to condition low-to-medium solids sewage sludge handled by a slow-speed multi-disc or screw press before screw press separation. The supplied range provides 89% minimum solids, 20-100 mesh particle size and a recommended 0.1-0.5% working solution. Grade selection is based on the actual sludge charge, solids concentration, upstream chemistry and equipment shear. The product is available in 25 kg PE bag packaging from Bluwat Chemicals. The ISO 14001 reference in the product title applies at manufacturer management-system level; current supporting documents should be confirmed with the sales team.

    Product Overview

    In municipal and decentralized sewage treatment, polymer purchasing should begin with the real separation problem rather than a generic request for PAM. This page addresses low-to-medium solids sewage sludge handled by a slow-speed multi-disc or screw press. The objective is to create a floc that matches the hydraulic loading, shear and drainage mechanism of the screw press. Cationic Polyacrylamide provides long polymer chains that connect destabilized particles into larger aggregates; the cationic charge also helps neutralize many negatively charged organic and biological surfaces. The result can be faster water release and improved solids capture when grade, preparation and dose are correct.

    PAM is not a complete treatment train. It acts on suspended and colloidal material that is already available for flocculation. Dissolved contaminants, stable emulsions, incompletely precipitated metals and uncontrolled pH require the appropriate upstream process. This boundary is particularly important when a visually clear filtrate can still contain dissolved COD, color, oil or metals.

    sludge dewatering polyacrylamide solutions(1).png
    Sludge Dewatering Problem

    The relevant feed is low-to-medium solids sewage sludge handled by a slow-speed multi-disc or screw press. The main operating difficulty is that small floc can escape through screen gaps, while sticky overdosed sludge can coat moving rings and restrict drainage. A weak program allows fines to escape and increases recycle loading. An excessive program may create slippery water, sticky cake, belt or cloth blinding, poor release and unnecessary chemical cost. The practical target is therefore not the largest floc in a beaker; it is visible, durable floc; clear drainage water; stable screen permeability; and continuous low-speed operation.

    Notice: Check the screw-press screen gap, feed solids and internal wash cycle before concluding that polymer dose is the limiting factor.

    How CPAM Supports the Separation Process
    1. Particle contact: The prepared CPAM solution disperses through the conditioned sludge so charged sites and suspended particles can contact the polymer chain.
    2. Charge response: The selected charge level reduces electrostatic stability where applicable. Charge demand depends on sludge source, upstream coagulants, pH, salts and soluble organics.
    3. Polymer bridging: Extended chains connect multiple particles into floc that is large enough to retain but open enough to release water.
    4. Equipment separation: The screw press uses screen drainage followed by gradual screw compression to separate the conditioned solids from the released liquid.
    5. Controlled optimization: Dose, solution concentration, mixing energy and injection point are adjusted together while the operator monitors capture, cake quality and equipment capacity.
    Recommended Addition Point and Equipment Fit

    Introduce the fully activated polymer at the following location: the press flocculation tank, using gentle mixing before sludge enters the thickening and compression zones. The point must provide uniform contact without exposing newly formed floc to unnecessary high shear. Where an inline mixer is used, begin with the minimum energy needed to distribute the solution. Where a flocculation tank is available, observe whether floc continues to grow or begins to break before it reaches the equipment.

    For the screw press, the operator should judge polymer performance together with feed solids, hydraulic load and machine settings. A polymer change can improve conditioning, but it cannot correct worn separation surfaces, blocked drainage paths, unsuitable mechanical settings, poor feed equalization or an overloaded machine.

    Grade Selection Guidance

    BLUFLOC CPAM is available across a 5-12 million molecular-weight range and 5-80% charge-degree range. Lower-charge or moderate-charge products may offer an economical starting point for some primary or mineral-containing sludges. Higher charge may be useful for fine biological or high-organic feeds, but it can also narrow the dosage window. Molecular weight influences bridging, floc size and shear response. No charge or molecular-weight label should be selected without a comparative test.

    • Test fresh, representative sludge at the normal feed-solids concentration.
    • Keep upstream chemistry and mechanical settings constant during each comparison.
    • Compare at least three doses for each candidate grade.
    • Prefer the lowest dose that achieves the required capture, drainage and cake handling.
    • Confirm the selected grade in a continuous equipment trial before bulk purchasing.
    BLUFLOC Powder PAM Typical Supply Range

    Property

    Specified Range

    Practical Relevance

    Appearance

    Off-white granular powder

    Dry, free-flowing product when correctly stored

    Ionic type

    Cationic

    Select by sludge surface chemistry and jar testing

    Particle size

    20-100 mesh

    Supports controlled dry-powder make-down

    Molecular weight

    5-12 million

    Screen grades for floc size, drainage and shear environment

    Charge range

    5-80% charge degree

    Match the charge demand of the actual sludge

    Solid content

    89% minimum

    Use active-product basis for cost and dose comparisons

    Bulk density

    About 0.8

    Useful for storage and feeder planning

    Residual monomer

    0.05% maximum

    TDS quality-control limit

    Working concentration

    0.1-0.5%

    Select dilution for activation, pumping and dispersion

    pH of 1% solution

    4-6

    Product-solution property, not a required sludge operating pH

    Storage temperature

    0-35°C

    Keep dry, shaded and protected from moisture

    Shelf life

    2 years

    Applies under appropriate storage conditions

    Technical values are taken from the supplied BLUFLOC Polyacrylamide Powder TDS. Final grade and dose must be confirmed using representative sludge and the actual equipment.

    Polymer Solution Preparation
    1. Fill a clean make-down tank with suitable water and start moderate agitation before adding powder.
    2. Meter the dry powder slowly and evenly into the moving water. Avoid dumping the product, which forms fish-eyes or gel lumps.
    3. Prepare a 0.1-0.5% solution. Choose the lower end where easier dispersion and accurate low-dose control are important; choose a higher concentration only when the system can mix, pump and dilute it reliably.
    4. Agitate at approximately 200-400 rpm for about one hour. Excessive mixer speed can cut polymer chains and reduce performance.
    5. Inspect the solution for undissolved particles before use. Keep the solution tank, transfer pump and dosing line clean and free of incompatible chemical residues.
    6. At the application point, dilute further when needed to improve distribution across the sludge stream. Do not combine concentrated PAM directly with coagulant in the same make-down tank.
    Bench Test and Equipment Trial
    1. Collect the sludge during representative municipal and decentralized sewage treatment operation and record source, temperature, pH, feed solids and upstream chemical additions.
    2. Prepare fresh CPAM solutions at a known concentration and screen several charge or molecular-weight options.
    3. Run a dose-response series with equal mixing. Observe initial floc formation, free-water release, supernatant clarity and resistance to gentle shear.
    4. Take the strongest candidates to the screw press. Keep feed rate and mechanical settings steady long enough to compare each condition.
    5. Record filtrate clarity, cake solids, solids capture, screen washing frequency, screw speed, throughput and polymer use. Convert consumption to active polymer per tonne of dry solids whenever the feed-solids data allow.
    6. Repeat the test under a second representative operating condition before approving the product and create a dose curve for routine control.
    Operating Performance Indicators

    Indicator Parameter

    Description & Assessment Basis

    Solids capture

    Measures whether fine particles remain with the cake rather than returning in filtrate, centrate or overflow.

    Cake or underflow solids

    Shows the mass and transport impact of water removal; compare on a consistent sampling basis.

    Liquid quality

    Track suspended solids and any process-specific parameter such as color, FOG or metals.

    Equipment capacity

    Assess feed rate, cycle time, torque, belt speed or hydraulic loading as applicable.

    Specific polymer use

    Report active polymer against dry solids, not only pump speed or solution volume.

    Total operating cost

    Balance polymer, energy, wash water, labor, throughput and sludge disposal rather than minimizing one item alone.

    Troubleshooting

    Fine solids in filtrate generally call for improved activation, more contact or a different charge. Slippery, gelatinous floc suggests overdosing or incomplete dry-powder dissolution.

    Symptom / Issue

    Recommended Action

    Small or weak floc

    Verify complete dissolution, increase contact gently, review charge demand and test another grade.

    Cloudy filtrate or centrate

    Check underdosing, high shear, feed-solids change, injection location and equipment loading.

    Sticky or gelatinous sludge

    Reduce dose, improve dilution and dispersion, and check for undissolved polymer or high grease.

    Good jar test, poor machine result

    Reproduce actual shear, residence time and dilution; inspect the transfer path and mechanical settings.

    Rising polymer consumption

    Measure feed solids, source blending, pH, conductivity, upstream chemical changes and sludge age.

    Packaging and Storage

    This buyer-intent configuration specifies 25 kg PE bag. The TDS also lists 25 kg kraft-paper or PE bags with inner plastic liners and 750 kg net big bags. Store unopened product in a dry, shaded area at 0-35°C. Protect it from moisture because dry PAM becomes extremely slippery when wet and partially hydrated powder can form difficult lumps. Use suitable dust control and follow the current SDS and site handling procedures. The stated shelf life is two years under appropriate storage conditions.

    Why Source BLUFLOC PAM from Bluwat Chemicals
    • Anionic, cationic and nonionic powder ranges for comparative application screening.
    • Technical discussion based on sludge source, upstream chemistry and dewatering equipment.
    • Jar-test samples available for grade and dose evaluation; international courier cost is borne by the customer and confirmed by the sales team, with reimbursement after a completed order under the applicable commercial arrangement.
    • 25 kg bags and 750 kg net big bags for trial, routine consumption and bulk handling needs.
    • Manufacturer management-system positioning referenced as ISO 9001in this page title; current supporting documents should be confirmed with the sales team.
    • Export experience serving water, wastewater and process-industry customers in multiple markets.
    Frequently Asked Questions
    QIs CPAM always the correct polymer for this sludge?

    No. CPAM is the intended starting product for this search, but actual particle charge, upstream chemicals and equipment shear determine the best ionic type and grade. Comparative testing is required.

    QDoes the solution pH in the title define the sludge operating pH?

    No. The stated pH is the TDS value for a 1% CPAM solution. It is not a universal process set point. Adjust sludge pH according to upstream treatment chemistry and the contaminants being controlled.

    QWhat working-solution concentration should the plant prepare?

    The supplied TDS recommends 0.1-0.5%. The final concentration should suit the make-down unit, dosing-pump range, dilution water and required dispersion at the application point.

    QHow should dose be compared on the screw press?

    Use active polymer per tonne of dry solids and compare it with capture, cake solids, throughput and liquid quality. Solution flow alone is misleading when concentration or feed solids change.

    QCan PAM solve poor precipitation, color removal or emulsion breaking?

    No. Complete those upstream reactions first. PAM mainly enlarges and captures suspended or precipitated solids so that the dewatering equipment can separate them.

    QCan Bluwat provide a sample and dosage recommendation?

    A free product sample can be arranged for evaluation. The customer bears the international courier charge, which is confirmed by the sales team and may be reimbursed after a completed order under the applicable commercial arrangement. A dose is proposed only after reviewing the sludge and test results.

    Request a Sludge Dewatering Evaluation

    Send Bluwat Chemicals the sludge source, daily wet-sludge flow, feed-solids concentration, current polymer and dose, upstream coagulants, screw press model or capacity, current cake solids, filtrate or centrate quality and the main operating problem. We can then narrow the BLUFLOC CPAM screening range and propose a bench-to-equipment trial plan. Final performance and consumption remain subject to the actual sample and site conditions.

    Leave Your Message