- Plant-Based Deodorant
- Water Treatment Chemicals
- Coagulant
-
Flocculant
- Polyacrylamide for Textile, Food & Process Industries
- Polyacrylamide for Oil, Gas & Drilling
- Polyacrylamide for Pulp&Paper
- Polyacrylamide for Mining & Mineral Processing
- Polyacrylamide for Sludge Dewatering
- Polyacrylamide for Water & Wastewater Clarification
- Polyacrylamide Emulsion
- Polyacrylamide Powder
- BWD-01 Water Decoloring Agent
Cationic Polyacrylamide CPAM 5-80% Charge Degree for Dissolved Air Flotation Sludge Dewatering CAS 9003-05-8 ISO 9001 Manufacturer 25kg PE Bag
Product Overview
In industrial wastewater pretreatment, polymer purchasing should begin with the real separation problem rather than a generic request for PAM. This page addresses flotation sludge containing biological solids, precipitates, surfactants, fats or separated oil. The objective is to create a floc that matches the hydraulic loading, shear and drainage mechanism of the downstream screw press, belt press, centrifuge or filter press. Cationic Polyacrylamide provides long polymer chains that connect destabilized particles into larger aggregates; the cationic charge also helps neutralize many negatively charged organic and biological surfaces. The result can be faster water release and improved solids capture when grade, preparation and dose are correct.
PAM is not a complete treatment train. It acts on suspended and colloidal material that is already available for flocculation. Dissolved contaminants, stable emulsions, incompletely precipitated metals and uncontrolled pH require the appropriate upstream process. This boundary is particularly important when a visually clear filtrate can still contain dissolved COD, color, oil or metals.

Sludge Dewatering Problem
The relevant feed is flotation sludge containing biological solids, precipitates, surfactants, fats or separated oil. The main operating difficulty is that entrained air, low density and residual surfactants make the float sludge bulky, variable and difficult to release water from. A weak program allows fines to escape and increases recycle loading. An excessive program may create slippery water, sticky cake, belt or cloth blinding, poor release and unnecessary chemical cost. The practical target is therefore not the largest floc in a beaker; it is collapse loose float structure, capture fines, improve feed consistency and increase downstream cake solids.
How CPAM Supports the Separation Process
- Particle contact: The prepared CPAM solution disperses through the conditioned sludge so charged sites and suspended particles can contact the polymer chain.
- Charge response: The selected charge level reduces electrostatic stability where applicable. Charge demand depends on sludge source, upstream coagulants, pH, salts and soluble organics.
- Polymer bridging: Extended chains connect multiple particles into floc that is large enough to retain but open enough to release water.
- Equipment separation: The downstream screw press, belt press, centrifuge or filter press uses the gravity, pressure or centrifugal separation mechanism selected by the plant to separate the conditioned solids from the released liquid.
- Controlled optimization: Dose, solution concentration, mixing energy and injection point are adjusted together while the operator monitors capture, cake quality and equipment capacity.
Recommended Addition Point and Equipment Fit
Introduce the fully activated polymer at the following location: after DAF skimming and equalization, in a dedicated sludge conditioning stage before the selected dewatering machine. The point must provide uniform contact without exposing newly formed floc to unnecessary high shear.
Grade Selection Guidance
BLUFLOC CPAM is available across a 5-12 million molecular-weight range and 5-80% charge-degree range. No charge or molecular-weight label should be selected without a comparative test.
- Test fresh, representative sludge at the normal feed-solids concentration.
- Keep upstream chemistry and mechanical settings constant during each comparison.
- Compare at least three doses for each candidate grade.
- Prefer the lowest dose that achieves the required capture, drainage and cake handling.
- Confirm the selected grade in a continuous equipment trial before bulk purchasing.
BLUFLOC Powder PAM Typical Supply Range
| Property | Specified Range | Practical Relevance |
|---|---|---|
| Appearance | Off-white granular powder | Dry, free-flowing product |
| Ionic type | Cationic | Select by sludge surface chemistry |
| Molecular weight | 5-12 million | Screen for floc size & shear |
| Solid content | 89% minimum | Use active-product basis |
| Shelf life | 2 years | Under appropriate conditions |
Polymer Solution Preparation
- Fill a clean make-down tank with suitable water and start moderate agitation before adding powder.
- Meter the dry powder slowly and evenly into the moving water to avoid fish-eyes.
- Prepare a 0.1-0.5% solution.
- Agitate at approximately 200-400 rpm for about one hour.
- Inspect the solution for undissolved particles before use.
Operating Performance Indicators
| Indicator | Description |
|---|---|
| Solids capture | Retention of fine particles in cake |
| Cake solids | Mass and transport impact of water removal |
| Liquid quality | Track suspended solids, color, FOG or metals |
Why Source BLUFLOC PAM from Bluwat Chemicals
- Anionic, cationic and nonionic powder ranges.
- Technical discussion based on sludge source and equipment.
- Jar-test samples available for evaluation.
- Flexible packaging: 25 kg bags and 750 kg net big bags.
- ISO 9001 certified management system.
Frequently Asked Questions
Is CPAM always the correct polymer for this sludge?
No. Comparative testing is required as particle charge and upstream chemicals determine the best grade.
Can Bluwat provide a sample and dosage recommendation?
Yes, a free product sample can be arranged for evaluation. The customer bears the international courier charge, which may be reimbursed after a completed order.
Request a Sludge Dewatering Evaluation
Send Bluwat Chemicals the sludge source, daily wet-sludge flow, feed-solids concentration, and equipment details. We can then narrow the BLUFLOC CPAM screening range and propose a bench-to-equipment trial plan.










