- Plant-Based Deodorant
- Water Treatment Chemicals
- Coagulant
-
Flocculant
- Polyacrylamide for Textile, Food & Process Industries
- Polyacrylamide for Oil, Gas & Drilling
- Polyacrylamide for Pulp&Paper
- Polyacrylamide for Mining & Mineral Processing
- Polyacrylamide for Sludge Dewatering
- Polyacrylamide for Water & Wastewater Clarification
- Polyacrylamide Emulsion
- Polyacrylamide Powder
- BWD-01 Water Decoloring Agent
Cationic Polyacrylamide CPAM Off-White Granular Powder 20-100 Mesh for Paint Wastewater Sludge Dewatering CAS 9003-05-8 ISO 9001 Manufacturer 25kg PE Bag
Product Overview
In paint and coatings wastewater treatment, polymer purchasing should begin with the real separation problem rather than a generic request for PAM. This page addresses coagulated sludge containing pigments, resins, latex, surfactants and solvent residues. The objective is to create a floc that matches the hydraulic loading, shear and drainage mechanism of the filter press, screw press or belt press. Cationic Polyacrylamide provides long polymer chains that connect destabilized particles into larger aggregates; the cationic charge also helps neutralize many negatively charged organic and biological surfaces. The result can be faster water release and improved solids capture when grade, preparation and dose are correct.
PAM is not a complete treatment train. It acts on suspended and colloidal material that is already available for flocculation. Dissolved contaminants, stable emulsions, incompletely precipitated metals and uncontrolled pH require the appropriate upstream process. This boundary is particularly important when a visually clear filtrate can still contain dissolved COD, color, oil or metals.

Sludge Dewatering Problem
The relevant feed is coagulated sludge containing pigments, resins, latex, surfactants and solvent residues. The main operating difficulty is that stable resin emulsions and fine pigments create sticky sludge that can blind cloth or pass into filtrate. A weak program allows fines to escape and increases recycle loading. An excessive program may create slippery water, sticky cake, belt or cloth blinding, poor release and unnecessary chemical cost. The practical target is therefore not the largest floc in a beaker; it is compact floc, clear filtrate, shorter press cycles and clean cake release.
Decolorizer, detackifier or coagulant treatment must first destabilize paint solids. CPAM then enlarges the formed particles for separation.
How CPAM Supports the Separation Process
- Particle contact: The prepared CPAM solution disperses through the conditioned sludge so charged sites and suspended particles can contact the polymer chain.
- Charge response: The selected charge level reduces electrostatic stability where applicable. Charge demand depends on sludge source, upstream coagulants, pH, salts and soluble organics.
- Polymer bridging: Extended chains connect multiple particles into floc that is large enough to retain but open enough to release water.
- Equipment separation: The filter press, screw press or belt press uses the gravity, pressure or centrifugal separation mechanism selected by the plant to separate the conditioned solids from the released liquid.
- Controlled optimization: Dose, solution concentration, mixing energy and injection point are adjusted together while the operator monitors capture, cake quality and equipment capacity.
Recommended Addition Point and Equipment Fit
Introduce the fully activated polymer at the following location: after paint detackification or emulsion breaking, PAC coagulation and pH adjustment. The point must provide uniform contact without exposing newly formed floc to unnecessary high shear.
Grade Selection Guidance
BLUFLOC CPAM is available across a 5-12 million molecular-weight range and 5-80% charge-degree range. Higher charge may be useful for fine biological or high-organic feeds, but it can also narrow the dosage window.
- Test fresh, representative sludge at the normal feed-solids concentration.
- Keep upstream chemistry and mechanical settings constant during each comparison.
- Compare at least three doses for each candidate grade.
- Prefer the lowest dose that achieves the required capture, drainage and cake handling.
- Confirm the selected grade in a continuous equipment trial before bulk purchasing.
BLUFLOC Powder PAM Typical Supply Range
| Property | Specified Range | Practical Relevance |
|---|---|---|
| Appearance | Off-white granular powder | Dry, free-flowing product |
| Ionic type | Cationic | Select by sludge surface chemistry |
| Molecular weight | 5-12 million | Screen grades for floc size |
| Charge range | 5-80% charge degree | Match the charge demand |
Polymer Solution Preparation
- Fill a clean make-down tank with suitable water and start moderate agitation.
- Meter the dry powder slowly and evenly into the moving water.
- Prepare a 0.1-0.5% solution.
- Agitate at approximately 200-400 rpm for about one hour.
- Inspect the solution for undissolved particles before use.
Bench Test and Equipment Trial
- Collect the sludge during representative operation.
- Prepare fresh CPAM solutions at a known concentration.
- Run a dose-response series with equal mixing.
- Take the strongest candidates to the filter press, screw press or belt press.
- Record filtrate color, turbidity, cake solids, and cycle time.
- Repeat the test under a second representative operating condition.
Operating Performance Indicators
| Indicator | Description |
|---|---|
| Solids capture | Measures if fine particles remain with cake. |
| Cake solids | Shows the impact of water removal. |
| Liquid quality | Track suspended solids, color, FOG or metals. |
Troubleshooting
Colored or milky filtrate often indicates incomplete resin destabilization. Verify upstream order and pH before increasing CPAM.
Frequently Asked Questions
Is CPAM always the correct polymer for this sludge?
No. CPAM is the intended starting product for this search, but actual particle charge, upstream chemicals and equipment shear determine the best ionic type and grade.
Request a Sludge Dewatering Evaluation
Send Bluwat Chemicals the sludge source, daily wet-sludge flow, feed-solids concentration, current polymer and dose, upstream coagulants, and current operating problems to receive a tailored evaluation.










