request to quote
Leave Your Message
Cationic Polyacrylamide CPAM Off-White Granular Powder 20-100 Mesh for Paper Mill Sludge Dewatering CAS 9003-05-8 ISO 9001 Manufacturer 750kg Net Big Bag
Polyacrylamide for Sludge Dewatering
Products Categories
Featured Products

Cationic Polyacrylamide CPAM Off-White Granular Powder 20-100 Mesh for Paper Mill Sludge Dewatering CAS 9003-05-8 ISO 9001 Manufacturer 750kg Net Big Bag

BLUFLOC Cationic Polyacrylamide (CPAM) is an off-white, water-soluble granular powder used to condition primary fiber and filler sludge, biological sludge, or a mixed mill sludge before screw press, belt press, centrifuge or filter press separation. The supplied range provides 89% minimum solids, 20-100 mesh particle size and a recommended 0.1-0.5% working solution. Grade selection is based on the actual sludge charge, solids concentration, upstream chemistry and equipment shear. The product is available in 750 kg net big bag packaging from Bluwat Chemicals. The ISO 9001 reference in the product title applies at manufacturer management-system level; current supporting documents should be confirmed with the sales team.

    Product Overview

    In pulp and paper wastewater treatment, polymer purchasing should begin with the real separation problem rather than a generic request for PAM. This page addresses primary fiber and filler sludge, biological sludge, or a mixed mill sludge. The objective is to create a floc that matches the hydraulic loading, shear and drainage mechanism of the screw press, belt press, centrifuge or filter press. Cationic Polyacrylamide provides long polymer chains that connect destabilized particles into larger aggregates; the cationic charge also helps neutralize many negatively charged organic and biological surfaces. The result can be faster water release and improved solids capture when grade, preparation and dose are correct.

    PAM is not a complete treatment train. It acts on suspended and colloidal material that is already available for flocculation. Dissolved contaminants, stable emulsions, incompletely precipitated metals and uncontrolled pH require the appropriate upstream process. This boundary is particularly important when a visually clear filtrate can still contain dissolved COD, color, oil or metals.

    sludge dewatering polyacrylamide solutions(1).png

    Sludge Dewatering Problem

    The relevant feed is primary fiber and filler sludge, biological sludge, or a mixed mill sludge. The main operating difficulty is that fiber, clay, calcium carbonate, coatings and wet-end chemicals create highly variable charge demand and ash content. A weak program allows fines to escape and increases recycle loading. An excessive program may create slippery water, sticky cake, belt or cloth blinding, poor release and unnecessary chemical cost. The practical target is therefore not the largest floc in a beaker; it is retain fibers and fillers, improve drainage, reduce filtrate solids and produce a transportable cake.

    Separate paper-machine retention chemistry from wastewater-sludge dewatering trials; the objectives, shear and dosage bases are different.

    How CPAM Supports the Separation Process

    1. Particle contact: The prepared CPAM solution disperses through the conditioned sludge so charged sites and suspended particles can contact the polymer chain.
    2. Charge response: The selected charge level reduces electrostatic stability where applicable. Charge demand depends on sludge source, upstream coagulants, pH, salts and soluble organics.
    3. Polymer bridging: Extended chains connect multiple particles into floc that is large enough to retain but open enough to release water.
    4. Equipment separation: The screw press, belt press, centrifuge or filter press uses the gravity, pressure or centrifugal separation mechanism selected by the plant to separate the conditioned solids from the released liquid.
    5. Controlled optimization: Dose, solution concentration, mixing energy and injection point are adjusted together while the operator monitors capture, cake quality and equipment capacity.

    Recommended Addition Point and Equipment Fit

    Introduce the fully activated polymer at the following location: after mill sludge blending and before mechanical dewatering, using low-shear contact that preserves fiber-polymer floc. The point must provide uniform contact without exposing newly formed floc to unnecessary high shear.

    Grade Selection Guidance

    BLUFLOC CPAM is available across a 5-12 million molecular-weight range and 5-80% charge-degree range. No charge or molecular-weight label should be selected without a comparative test.

    • Test fresh, representative sludge at the normal feed-solids concentration.
    • Keep upstream chemistry and mechanical settings constant during each comparison.
    • Compare at least three doses for each candidate grade.

    BLUFLOC Powder PAM Typical Supply Range

    Property Specified Range Practical Relevance
    Appearance Off-white granular powder Dry, free-flowing product when correctly stored
    Ionic type Cationic Select by sludge surface chemistry and jar testing
    Molecular weight 5-12 million Screen grades for floc size, drainage and shear
    Charge range 5-80% charge degree Match the charge demand of the actual sludge

    Polymer Solution Preparation

    1. Fill a clean make-down tank with suitable water and start moderate agitation before adding powder.
    2. Meter the dry powder slowly and evenly into the moving water.
    3. Prepare a 0.1-0.5% solution.
    4. Agitate at approximately 200-400 rpm for about one hour.

    Operating Performance Indicators

    Indicator Description
    Solids capture Measures whether fine particles remain with the cake.
    Cake solids Shows the mass and transport impact of water removal.
    Equipment capacity Assess feed rate, cycle time, torque or hydraulic loading.

    Troubleshooting

    A grade that works on primary fiber sludge may fail on biological sludge. Test representative blend ratios and monitor broke or grade-change events.

    Why Source BLUFLOC PAM from Bluwat Chemicals

    • Anionic, cationic and nonionic powder ranges for comparative application screening.
    • Technical discussion based on sludge source, upstream chemistry and dewatering equipment.
    • Export experience serving water, wastewater and process-industry customers.

    Frequently Asked Questions

    Is CPAM always the correct polymer for this sludge?

    No. CPAM is the intended starting product for this search, but actual particle charge, upstream chemicals and equipment shear determine the best ionic type and grade.

    Can Bluwat provide a sample and dosage recommendation?

    A free product sample can be arranged for evaluation. The customer bears the international courier charge, which is confirmed by the sales team.

    Leave Your Message