Cationic Polyacrylamide CPAM Off-White Granular Powder 20-100 Mesh for Slaughterhouse Sludge Dewatering CAS 9003-05-8 25kg PE Bag
Polyacrylamide for Sludge Dewatering
Products Categories
Featured Products

Cationic Polyacrylamide CPAM Off-White Granular Powder 20-100 Mesh for Slaughterhouse Sludge Dewatering CAS 9003-05-8 25kg PE Bag

BLUFLOC Cationic Polyacrylamide (CPAM) is an off-white, water-soluble granular powder used to condition screenings fines, DAF float and biological sludge containing blood proteins, fats and tissue particles before screw press, belt press or centrifuge separation. The supplied range provides 89% minimum solids, 20-100 mesh particle size and a recommended 0.1-0.5% working solution. Grade selection is based on the actual sludge charge, solids concentration, upstream chemistry and equipment shear. The product is available in 25 kg PE bag packaging from Bluwat Chemicals. The ISO 9001 reference in the product title applies at manufacturer management-system level; current supporting documents should be confirmed with the sales team.

    Product Overview

    In slaughterhouse wastewater treatment, polymer purchasing should begin with the real separation problem rather than a generic request for PAM. This page addresses screenings fines, DAF float and biological sludge containing blood proteins, fats and tissue particles. The objective is to create a floc that matches the hydraulic loading, shear and drainage mechanism of the screw press, belt press or centrifuge. Cationic Polyacrylamide provides long polymer chains that connect destabilized particles into larger aggregates; the cationic charge also helps neutralize many negatively charged organic and biological surfaces. The result can be faster water release and improved solids capture when grade, preparation and dose are correct.

    PAM is not a complete treatment train. It acts on suspended and colloidal material that is already available for flocculation. Dissolved contaminants, stable emulsions, incompletely precipitated metals and uncontrolled pH require the appropriate upstream process. This boundary is particularly important when a visually clear filtrate can still contain dissolved COD, color, oil or metals.

    sludge dewatering polyacrylamide solutions

    Sludge Dewatering Problem

    The relevant feed is screenings fines, DAF float and biological sludge containing blood proteins, fats and tissue particles. The main operating difficulty is that rapid organic decay, fat variability and protein-rich colloids can create odor, stickiness and unstable drainage. A weak program allows fines to escape and increases recycle loading. An excessive program may create slippery water, sticky cake, belt or cloth blinding, poor release and unnecessary chemical cost. The practical target is therefore not the largest floc in a beaker; it is fast conditioning, high capture, clean drainage and reduced wet sludge for transport.

    Note: Screening, FOG control, temperature and residence time should be managed before polymer optimization.

    How CPAM Supports the Separation Process

    1. Particle contact: The prepared CPAM solution disperses through the conditioned sludge so charged sites and suspended particles can contact the polymer chain.
    2. Charge response: The selected charge level reduces electrostatic stability where applicable. Charge demand depends on sludge source, upstream coagulants, pH, salts and soluble organics.
    3. Polymer bridging: Extended chains connect multiple particles into floc that is large enough to retain but open enough to release water.
    4. Equipment separation: The screw press, belt press or centrifuge uses the gravity, pressure or centrifugal separation mechanism selected by the plant to separate the conditioned solids from the released liquid.
    5. Controlled optimization: Dose, solution concentration, mixing energy and injection point are adjusted together while the operator monitors capture, cake quality and equipment capacity.

    Recommended Addition Point and Equipment Fit

    Introduce the fully activated polymer at the following location: after coarse screening, grease removal and sludge equalization, before mechanical dewatering. The point must provide uniform contact without exposing newly formed floc to unnecessary high shear. Where an inline mixer is used, begin with the minimum energy needed to distribute the solution. Where a flocculation tank is available, observe whether floc continues to grow or begins to break before it reaches the equipment.

    Grade Selection Guidance

    BLUFLOC CPAM is available across a 5-12 million molecular-weight range and 5-80% charge-degree range. Lower-charge or moderate-charge products may offer an economical starting point for some primary or mineral-containing sludges. Higher charge may be useful for fine biological or high-organic feeds, but it can also narrow the dosage window. Molecular weight influences bridging, floc size and shear response.

    • Test fresh, representative sludge at the normal feed-solids concentration.
    • Keep upstream chemistry and mechanical settings constant during each comparison.
    • Compare at least three doses for each candidate grade.
    • Prefer the lowest dose that achieves the required capture, drainage and cake handling.

    BLUFLOC Powder PAM Typical Supply Range

    Property Specified Range Practical Relevance
    Appearance Off-white granular powder Dry, free-flowing product
    Ionic type Cationic Select by sludge chemistry
    Molecular weight 5-12 million Screen for floc size
    Charge range 5-80% Match sludge demand

    Polymer Solution Preparation

    1. Fill a clean make-down tank with suitable water and start moderate agitation.
    2. Meter the dry powder slowly and evenly into the moving water.
    3. Prepare a 0.1-0.5% solution for optimal activation.
    4. Agitate at 200-400 rpm for about one hour.

    Troubleshooting

    Issue Action
    Small or weak floc Verify dissolution, review charge demand
    Cloudy filtrate Check underdosing, high shear
    Sticky sludge Reduce dose, improve dispersion

    Frequently Asked Questions

    Is CPAM always the correct polymer?

    No. Comparative testing is required based on particle charge and equipment shear.

    Can Bluwat provide a sample?

    Yes, a free product sample can be arranged for evaluation; customer bears courier charges.

    Leave Your Message