Cationic Polyacrylamide CPAM pH 4-6 in 1% Solution for Primary Sewage Sludge Conditioning CAS 9003-05-8 ISO 9001 Manufacturer 25kg PE Bag
Polyacrylamide for Sludge Dewatering
Products Categories
Featured Products

Cationic Polyacrylamide CPAM pH 4-6 in 1% Solution for Primary Sewage Sludge Conditioning CAS 9003-05-8 ISO 9001 Manufacturer 25kg PE Bag

BLUFLOC Cationic Polyacrylamide (CPAM) is an off-white, water-soluble granular powder used to condition settled primary sludge containing readily settleable solids, grease, fibers and grit before thickener or mechanical dewatering equipment separation. The supplied range provides 89% minimum solids, 20-100 mesh particle size and a recommended 0.1-0.5% working solution. Grade selection is based on the actual sludge charge, solids concentration, upstream chemistry and equipment shear. The product is available in 25 kg PE bag packaging from Bluwat Chemicals. The ISO 14001 reference in the product title applies at manufacturer management-system level; current supporting documents should be confirmed with the sales team.

    Product Overview

    In municipal primary treatment, polymer purchasing should begin with the real separation problem rather than a generic request for PAM. This page addresses settled primary sludge containing readily settleable solids, grease, fibers and grit. The objective is to create a floc that matches the hydraulic loading, shear and drainage mechanism of the thickener or mechanical dewatering equipment. Cationic Polyacrylamide provides long polymer chains that connect destabilized particles into larger aggregates; the cationic charge also helps neutralize many negatively charged organic and biological surfaces. The result can be faster water release and improved solids capture when grade, preparation and dose are correct.

    PAM is not a complete treatment train. It acts on suspended and colloidal material that is already available for flocculation. Dissolved contaminants, stable emulsions, incompletely precipitated metals and uncontrolled pH require the appropriate upstream process. This boundary is particularly important when a visually clear filtrate can still contain dissolved COD, color, oil or metals.

    sludge dewatering polyacrylamide solutions(1).png

    Sludge Dewatering Problem

    The relevant feed is settled primary sludge containing readily settleable solids, grease, fibers and grit. The main operating difficulty is that the feed is denser than biological sludge but grease and variable solids can disturb floc formation and cake release. A weak program allows fines to escape and increases recycle loading. An excessive program may create slippery water, sticky cake, belt or cloth blinding, poor release and unnecessary chemical cost. The practical target is therefore not the largest floc in a beaker; it is uniform conditioning, rapid drainage, fiber capture and stable downstream loading.

    ⚠️
    Important: Remove grit and control grease slugs before polymer conditioning to protect mixers, pumps and dewatering surfaces.

    How CPAM Supports the Separation Process

    1. Particle contact: The prepared CPAM solution disperses through the conditioned sludge so charged sites and suspended particles can contact the polymer chain.
    2. Charge response: The selected charge level reduces electrostatic stability where applicable. Charge demand depends on sludge source, upstream coagulants, pH, salts and soluble organics.
    3. Polymer bridging: Extended chains connect multiple particles into floc that is large enough to retain but open enough to release water.
    4. Equipment separation: The thickener or mechanical dewatering equipment uses gravity or flotation thickening as configured by the plant to separate the conditioned solids from the released liquid.
    5. Controlled optimization: Dose, solution concentration, mixing energy and injection point are adjusted together while the operator monitors capture, cake quality and equipment capacity.

    Recommended Addition Point and Equipment Fit

    Introduce the fully activated polymer at the following location: after grit removal and sludge equalization, before thickening or the final dewatering device. The point must provide uniform contact without exposing newly formed floc to unnecessary high shear. Where an inline mixer is used, begin with the minimum energy needed to distribute the solution. Where a flocculation tank is available, observe whether floc continues to grow or begins to break before it reaches the equipment.

    For the thickener or mechanical dewatering equipment, the operator should judge polymer performance together with feed solids, hydraulic load and machine settings. A polymer change can improve conditioning, but it cannot correct worn separation surfaces, blocked drainage paths, unsuitable mechanical settings, poor feed equalization or an overloaded machine.

    Grade Selection Guidance

    BLUFLOC CPAM is available across a 5-12 million molecular-weight range and 5-80% charge-degree range. Lower-charge or moderate-charge products may offer an economical starting point for some primary or mineral-containing sludges. Higher charge may be useful for fine biological or high-organic feeds, but it can also narrow the dosage window. Molecular weight influences bridging, floc size and shear response. No charge or molecular-weight label should be selected without a comparative test.

    • Test fresh, representative sludge at the normal feed-solids concentration.
    • Keep upstream chemistry and mechanical settings constant during each comparison.
    • Compare at least three doses for each candidate grade.
    • Prefer the lowest dose that achieves the required capture, drainage and cake handling.
    • Confirm the selected grade in a continuous equipment trial before bulk purchasing.

    BLUFLOC Powder PAM Typical Supply Range

    Property Specified Range Practical Relevance
    Appearance Off-white granular powder Dry, free-flowing product when correctly stored
    Ionic type Cationic Select by sludge surface chemistry and jar testing
    Particle size 20-100 mesh Supports controlled dry-powder make-down
    Molecular weight 5-12 million Screen grades for floc size, drainage and shear environment
    Charge range 5-80% charge degree Match the charge demand of the actual sludge
    Solid content 89% minimum Use active-product basis for cost and dose comparisons
    Bulk density About 0.8 Useful for storage and feeder planning
    Residual monomer 0.05% maximum TDS quality-control limit
    Working concentration 0.1-0.5% Select dilution for activation, pumping and dispersion
    pH of 1% solution 4-6 Product-solution property, not a required sludge operating pH
    Storage temperature 0-35°C Keep dry, shaded and protected from moisture
    Shelf life 2 years Applies under appropriate storage conditions

    Polymer Solution Preparation

    1. Fill a clean make-down tank with suitable water and start moderate agitation before adding powder.
    2. Meter the dry powder slowly and evenly into the moving water. Avoid dumping the product, which forms fish-eyes or gel lumps.
    3. Prepare a 0.1-0.5% solution. Choose the lower end where easier dispersion and accurate low-dose control are important; choose a higher concentration only when the system can mix, pump and dilute it reliably.
    4. Agitate at approximately 200-400 rpm for about one hour. Excessive mixer speed can cut polymer chains and reduce performance.
    5. Inspect the solution for undissolved particles before use. Keep the solution tank, transfer pump and dosing line clean and free of incompatible chemical residues.
    6. At the application point, dilute further when needed to improve distribution across the sludge stream.

    Bench Test and Equipment Trial

    1. Collect the sludge during representative municipal primary treatment operation.
    2. Prepare fresh CPAM solutions at a known concentration and screen several charge or molecular-weight options.
    3. Run a dose-response series with equal mixing. Observe initial floc formation and supernatant clarity.
    4. Take the strongest candidates to the thickener or mechanical dewatering equipment.
    5. Record supernatant or filtrate clarity, drainage, cake solids, equipment loading and polymer use.
    6. Repeat the test under a second representative operating condition before approving the product.

    Operating Performance Indicators

    Indicator Description
    Solids capture Measures whether fine particles remain with the cake.
    Cake or underflow solids Shows the mass and transport impact of water removal.
    Liquid quality Track suspended solids and process-specific parameters.
    Equipment capacity Assess feed rate, cycle time, torque, or hydraulic loading.
    Specific polymer use Report active polymer against dry solids.

    Troubleshooting

    Rapid dose changes often follow feed-solids variation. Control sludge withdrawal and base dosing on dry-solids loading instead of only wet flow.

    Packaging and Storage

    This buyer-intent configuration specifies 25 kg PE bag. Store unopened product in a dry, shaded area at 0-35°C. Protect it from moisture. The stated shelf life is two years under appropriate storage conditions.

    Why Source BLUFLOC PAM from Bluwat Chemicals

    • Anionic, cationic and nonionic powder ranges for comparative application screening.
    • Technical discussion based on sludge source, upstream chemistry and dewatering equipment.
    • Jar-test samples available for grade and dose evaluation.
    • 25 kg bags and 750 kg net big bags for trial and bulk handling.
    • Export experience serving water, wastewater and process-industry customers.

    Frequently Asked Questions

    Is CPAM always the correct polymer for this sludge?

    No. CPAM is the intended starting product for this search, but actual particle charge, upstream chemicals and equipment shear determine the best ionic type and grade. Comparative testing is required.

    Can Bluwat provide a sample and dosage recommendation?

    A free product sample can be arranged for evaluation. The customer bears the international courier charge. A dose is proposed only after reviewing the sludge and test results.

    Request a Sludge Dewatering Evaluation

    Send Bluwat Chemicals the sludge source, daily wet-sludge flow, feed-solids concentration, current polymer and dose, upstream coagulants, equipment model or capacity and the main operating problem. We can then narrow the BLUFLOC CPAM screening range and propose a bench-to-equipment trial plan.

    Leave Your Message