request to quote
Leave Your Message
Liquid PHPA Polymer for Oilfield Fracturing Fluid Formulations
Polyacrylamide Emulsion
Products Categories
Featured Products

Liquid PHPA Polymer for Oilfield Fracturing Fluid Formulations

BLUFLOC PHPA emulsion is a very-high-molecular-weight, high-charge liquid polymer candidate for polymer fracturing fluid formulation. EC8050 and EA5620 require grade-specific confirmation and application testing.

    Product Introduction

    A fracturing fluid is a formulation containing water, polymer, proppant, and application-specific additives, all of which can interact during high-rate mixing and pumping.

    The polymer cannot be qualified separately from the additives, source water, equipment, proppant, formation, and post-treatment objectives. BLUFLOC EC8050 and EA5620 are the two PHPA emulsion grades listed in the supplied family TDS. Both are shown as very-high-molecular-weight, high-charge, milky-white emulsions with 38-40% solid content. The TDS does not assign them different application roles, so final selection must come from current grade documents and representative testing.

    PHPA Bluwat压缩.jpg

    Application Challenges

    • The polymer cannot be qualified separately from the additives, source water, equipment, proppant, formation, and post-treatment objectives.
    • Rapid hydration and dispersion at high-rate continuous mixing
    • Friction performance that changes with brine, recycled water, iron, and suspended solids
    • Shear degradation through pumps, restrictions, and perforations

    How the PHPA Emulsion Works

    Polyacrylamide is used as a friction-reducing polymer in water-based fracturing fluids because an effective dissolved chain can reduce frictional pressure during high-rate pumping. The supplied PHPA TDS also lists fracturing-fluid use, but it does not publish friction-reduction, temperature, brine-tolerance, breaker-response, or residue data for EC8050 or EA5620. These grades therefore remain screening candidates until a full fluid program is qualified.

    Very-high molecular weight provides long-chain reach, while the stated high charge describes the broad grade class. Neither description alone predicts field performance. Preparation quality, dissolved ions, pH, temperature, solids, shear, aging, and the complete chemical package can change the observed result.

    💡
    Important selection note: The grades below are screening candidates, not a fixed prescription. Final selection, preparation, dose, addition point, and performance acceptance require representative laboratory and field or plant trials.

    Recommended BLUFLOC Grade Screening

    Grade Molecular Weight Charge Screening Position
    EC8050 Very High High Screening candidate; no grade-specific application role stated
    EA5620 Very High High Screening candidate; no grade-specific application role stated

    TDS Specifications

    TDS Item EC8050 EA5620
    Product form Emulsion Emulsion
    Molecular weight Very High Very High
    Charge degree High High
    Appearance Milky white Milky white
    Solid content 38-40% 38-40%
    Bulk density About 1.0 About 1.0
    Specific gravity at 25°C 1.01-1.05 1.01-1.05
    Shelf life 6 months 6 months
    Packaging 1000 kg IBC drum 1000 kg IBC drum
    📋
    TDS confirmation note: Exact active content, viscosity, specification limits, shelf life, and preparation instructions should be confirmed on the current grade-specific TDS and order specification.

    The supplied family TDS contains a general preparation section that refers to a polymer eductor or dry-powder feeder. It does not provide a separate inversion or make-down procedure for EC8050 and EA5620 emulsions. Do not automatically apply powder preparation instructions to the emulsion grades; obtain the current grade-specific emulsion procedure before commissioning.

    Application Advantages to Evaluate

    • Potential fit for the defined liquid phpa polymer fracturing fluid formulation duty after representative testing
    • Very-high-molecular-weight PHPA emulsion format for liquid handling and metering
    • High-charge classification stated for both EC8050 and EA5620 in the supplied TDS
    • PHPA-family compatibility claim covering biopolymers, PAC, and CMC, subject to formulation testing
    • Factory-direct documentation, sample screening, order coordination, and export support

    Recommended Evaluation and Dosing Workflow

    1. Define the water source, salinity, hardness, iron, suspended solids, temperature, rate, tubular geometry, and target pressure reduction.
    2. Confirm the emulsion-specific make-down equipment and measure active polymer rather than comparing neat-product volume alone.
    3. Run friction-loop testing across dose, rate, brine, temperature, and shear with the complete additive package.
    4. Evaluate hydration time, screenability, residue, breaker response where relevant, and recovered-water compatibility.
    5. Conduct a controlled field stage only after laboratory acceptance criteria and contingency actions are agreed.

    Product Selection and Compatibility

    Use a complete-fluid qualification plan that includes additive order, continuous-mix equipment, friction, proppant transport where relevant, breaker response, residue, and flowback compatibility.

    Compare candidates on active-polymer mass and total operating outcome. Neat-emulsion price per kilogram can be misleading when active content, make-down efficiency, dose, equipment throughput, solids or fluid quality, drilling performance, logistics, and downstream costs differ.

    Operating Indicators to Record

    • Complete-fluid compatibility
    • Friction and pressure behavior
    • Proppant handling if applicable
    • Breaker and residue response
    • Flowback and produced-water compatibility

    Troubleshooting Note

    ⚠️
    If performance drifts: If the polymer works in water alone but not in the complete package, isolate additive-order and compatibility effects before increasing dose.

    Packaging, Storage, and Safe Handling

    The supplied TDS specifies 1000 kg IBC drum packaging for liquid products. Store the product in its original packaging in a cool, dry place away from sources of heat, flame, and direct sunlight. The stated shelf life for the emulsion products is 6 months. Follow the current SDS for handling, spill control, personal protection, transport classification, and disposal. Polymer spills may create a severe slip hazard and should be contained and cleaned promptly.

    Why Choose Bluwat Chemicals

    • More than 25 years of water-treatment chemical manufacturing experience since 2000.
    • Three production bases supporting factory-direct supply, batch coordination, and export planning.
    • Export experience serving customers in more than 80 countries and regions.
    • Technical screening support based on the customer's drilling fluid, formation sample, brine, or produced-water conditions.
    • TDS, SDS, COA, packing details, and available company-level certification documents can be supplied for order review.

    For liquid phpa polymer fracturing fluid formulation, Bluwat can review the target duty, prepare a screening plan, compare the TDS-listed emulsion grades, and define laboratory and field acceptance indicators with the customer. Company-level certificates or management-system documents should not be represented as grade-specific application approvals unless the applicable certificate explicitly says so.

    Quality Control and Technical Support

    • Confirm the selected grade, current specification, order limits, and documentation before production.
    • Screen EC8050 and EA5620 with representative fluids because the supplied family TDS does not assign different application roles to the two grades.
    • Record water chemistry, temperature, shear history, mixing sequence, and baseline fluid properties during laboratory work.
    • Scale up only after agreed performance indicators and operating limits are demonstrated under representative conditions.

    Frequently Asked Questions

    QDoes PHPA replace guar in every frac design?

    No. Slickwater drag reduction and gel-based proppant transport are different design objectives.

    QShould breaker compatibility be tested?

    Yes, whenever the formulation requires controlled polymer degradation or cleanup.

    QDoes the TDS provide a guaranteed friction-reduction percentage?

    No. No friction-loop result or guaranteed percentage is stated for EC8050 or EA5620.

    QCan the product be selected without testing the actual frac water?

    No. Recycled water, salts, iron, solids, and the complete additive package can materially change performance.

    Leave Your Message