How Bluwat Tests Poly Aluminum Chloride (PAC) Quality
PAC is a pre-hydrolyzed aluminum coagulant. Its performance is affected by active aluminum content, degree of hydrolysis, insoluble matter, solution acidity, trace impurities and the characteristics of the water being treated. No single laboratory result can describe all of these factors.
For this reason, Bluwat's PAC quality evaluation is organized into three layers:
- Physical inspection:appearance, solution condition and, for liquid PAC, density.
- Chemical analysis: aluminum oxide content, basicity, pH, insoluble matter, iron and trace elements.
- Application verification: jar testing with representative source water when coagulation performance must be confirmed.
1. Representative Sampling and Sample Preparation
Reliable testing starts before the sample reAches the instrument. A laboratory result represents only the material actually collected, so the sampling plan must account for possible variation within a tank, drum or bag.
Liquid PAC
Liquid material is sampled from different depths of the PACkage or storage tank. The portions are combined and mixed to form a representative composite sample. The sample container must be clean, dry, chemically compatible and tightly sealed.
Solid PAC
For bagged powder or granules, samples are collected from selected PACkages using a suitable sampler inserted into the material. The portions are combined, mixed and reduced by an appropriate sample-splitting method without changing the composition.
Identification and retention
EAch laboratory sample is labeled with the product name, batch number, sampling date and sampler information. One portion is used for testing and a separately sealed portion can be retained for traceability or repeat analysis.
2. Appearance Inspection
The sample is examined under suitable lighting for color, clarity, uniformity, visible contamination, caking or unusual sediment. Liquid PAC should be checked for separation or suspended foreign matter. Solid PAC should be inspected for uniform powder or granule condition and evidence of moisture absorption.
Appearance is a useful first screening step, but it is not a substitute for chemical testing. Differences in raw materials and production conditions can affect color without directly predicting coagulation performance.
3. Aluminum Oxide Content by EDTA Complexometric Back-Titration
Aluminum oxide content is one of the main composition measurements for PAC. The reference approach uses complexometric titration.
Method principle
The PAC sample is dissolved and acid-treated to break down polymerized aluminum species. A measured excess of EDTA is then added. EDTA forms a stable complex with aluminum ions. The EDTA remaining after the reaction is back-titrated with a standardized metal solution.
General procedure
- Accurately weigh the liquid or solid PAC sample.
- Dissolve it in laboratory water and transfer it quantitatively to a volumetric flask.
- Filter the prepared solution if it is visibly turbid, using the filtration procedure specified by the controlled method.
- Transfer a measured aliquot, add acid and heat briefly to depolymerize the aluminum species.
- Add a known excess of EDTA and adjust the reaction conditions so that aluminum-EDTA complex formation is complete.
- Add the required buffer and indicator.
- Back-titrate the unreacted EDTA to the specified color endpoint.
- Run a reagent blank in parallel.
4. Basicity by Acid-Base Titration
Basicity reflects the degree of hydroxylation of PAC and is closely related to its hydrolysis behavior in water.
Method principle
A measured amount of standard hydrochloric acid is added to the prepared PAC solution. Potassium fluoride is then used to mask aluminum ions. The remaining acid is titrated with standardized sodium hydroxide using phenolphthalein to indicate the endpoint.
5. Density of Liquid PAC
Density is measured only for liquid PAC. A clean, dry measuring cylinder is filled carefully so that no air bubbles remain. The sample is brought to the controlled reference temperature in a constant-temperature bath. A calibrated hydrometer is lowered slowly into the liquid and allowed to stabilize without touching the wall.
6. Water-Insoluble Matter by Filtration and Gravimetry
This test measures the portion of the product that remains undissolved under defined acidic dissolution conditions.
7. pH Measurement of a Standardized PAC Solution
The pH test is performed on a PAC solution prepared at the concentration specified by the applicable method, rather than by placing the electrode directly into concentrated liquid PAC or an arbitrarily prepared powder solution.
8. Iron Determination
Iron is determined according to the applicable water-treatment-agent method, such as GB/T 22596 referenced by GB 15892-2020.
9. Arsenic by Atomic Fluorescence Spectrometry
The reference method for arsenic uses hydride-generation atomic fluorescence spectrometry.
10. Lead and Cadmium by Atomic Absorption Spectrometry
Lead and cadmium can be measured using electrothermal atomic absorption spectrometry. The PAC sample is acid-treated, diluted quantitatively and introduced into a graphite or other suitable electrothermal atomizer.
11. Mercury by Atomic Fluorescence or Cold-Vapor Atomic Absorption
The reference mercury method uses atomic fluorescence spectrometry after acid digestion. In an acidic medium, a borohydride reagent reduces mercury to elemental vapor.
12. Chromium by Electrothermal Atomic Absorption Spectrometry
For chromium determination, the acid-prepared PAC solution is analyzed by electrothermal atomic absorption.
13. Coagulation Performance by Jar Test
Chemical analysis confirms composition and impurity control, but a jar test shows how PAC behaves in actual water.
Laboratory Quality-Control Practices
Reliable PAC testing depends as much on quality control as on the analytical technique itself. A controlled laboratory workflow should include:
- Calibrated balances, volumetric equipment, pH meters and analytical instruments.
- Documented reagent preparation and titrant standardization.
- Reagent blanks, calibration standards and verification samples.
How Bluwat Reports PAC Quality
For export orders, the Certificate of Analysis identifies the product and batch and reports the agreed inspection items. Supporting product documentation can include the Technical Data Sheet, Safety Data Sheet, packing list, invoice, certificate of origin and other documents required for the shipment or destination market.