request to quote
Leave Your Message

Near-Black Dye Wastewater Clarified With a Four-Reagent Programme

2026-08-21
LAB JAR TEST RECORD · TEXTILE & DYE EFFLUENT

Near-Black Dye Wastewater Clarified With a Four-Reagent Programme

A dye effluent so dark it read as opaque black in the bottle. In the laboratory we ran a four-step jar test — 1.3 kg/t decoloring agent, 3.3 kg/t PAC, caustic flake to pH 7, then 3 g/t anionic PAM. After 2–3 minutes of settling the supernatant ran clear with a faint yellow cast.

Industry
Dye & textile effluent
Challenge
Near-opaque black colour
Programme
Decolorant + PAC + APAM
Settling
2 – 3 minutes
Raw black dye effluent beside dosed jar-test beakers in the Bluwat water treatment laboratory

Raw black dye effluent (left) beside the dosed jar-test beakers. Bench-scale record from our water treatment laboratory.

01 — The Challenge

What makes this effluent difficult

Black is the hardest shade to treat. It is almost never a single dye — it is a blend of several chromophores layered until no light passes through. That creates four practical problems:

Light cannot pass, so you cannot judge progress

Until a large share of the colour is removed the liquor looks unchanged. Operators routinely overdose because nothing appears to be happening.

Mixed chromophores need mixed mechanisms

A blend of dyes rarely responds to one reagent. Charge neutralisation alone leaves a residual tint that no extra dose will clear.

High colour load means high reagent demand

A dose measured in kilograms per tonne, not grams. Getting the sequence wrong is expensive at this scale.

pH drifts as you dose

Both the decolorant and PAC shift the pH. Left uncorrected, the polymer added afterwards works at a fraction of its caPACity.

The sample in this case is typical: a liquor with no visible transparency at all. The customer’s question was the practical one — what does it take, and in what order?

02 — The Programme

The dosing programme, step by step

Four moves, eAch one preparing the next. The order matters more than any single dosage.

Step Action Dosage / Setpoint Why It Matters
1 Dose the decoloring agent 1.3 kg/t Breaks the chromophore system. The cationic decolorant neutralises the anionic charge on the dissolved colour bodies and converts them from dissolved to particulate.
2 Dose PAC 3.3 kg/t Charge neutralisation and micro-flocculation. The destabilised colour aggregates into fine visible flocs.
3 Correct pH with caustic flake 350 g/t Brings the liquor to approximately pH 7. This is the window in which the polymer that follows performs; dosing PAM outside it wastes product.
4 Dose anionic PAM 3 g/t Bridges the fine flocs into large, dense aggregates that settle fast enough to separate cleanly.
Why PAC as well as a decolorant?The decolorant changes the state of the colour — dissolved to particulate. PAC then builds those particles into a floc structure and sweeps out suspended matter at the same time. On a load this heavy, the decolorant alone leaves fine material that will not settle.
Why only 3 g/t of polymer? Because by that point the work is done. Anionic PAM is a bridging agent, not a colour remover — it needs only enough chain length to link flocs that already exist. It is the cheapest item in the programme and the one that makes the result visible.
03 — Observations

What happened at each stage

Raw sample

Opaque black liquor with light suspended matter. No transparency at any depth.

After the decoloring agent

The colour system breaks down and the liquor begins to lose its depth as the colour bodies are destabilised.

After PAC

Fine flocs appear throughout the liquor and start to carry colour out of the water phase.

After pH correction to 7

The liquor is brought into the reaction window before any polymer is added.

After anionic PAM, 2–3 min settling

Flocs grow, settle, and leave a clear supernatant with a faint yellow cast.

Reproducibility note: this is a bench-scale jar test on one sample. Every effluent differs. Confirm the dosage on your own water before scaling up.
04 — The Result

Clear supernatant with a faint yellow cast

At the end of the sequence the water phase and the coloured solid phase separate cleanly. From an opaque black starting point, 2–3 minutes of settling produced a clear supernatant retaining only a light yellow tone — achieved with 1.3 kg/t decoloring agent, 3.3 kg/t PAC, 350 g/t caustic flake and 3 g/t anionic PAM.

Fast separation

Flocs settle in 2–3 minutes, which suits both sedimentation basins and DAF units.

Very low polymer demand

3 g/t of PAM. Polymer cost is negligible next to the decolorant and PAC.

Standard equipment

Three dosing points and one pH check. No specialist plant required.

Honest limit

A faint yellow cast remains. Reaching true water-clear needs a polishing stage — see the FAQ.

05 — Scale-Up

From jar test to full-scale dosing

1 kg/t = 1,000 ppm   ·   1 g/t = 1 ppm   ·   1 tonne of wastewater = 1 m³
Treated Flow Decoloring Agent
@ 1.3 kg/t
PAC
@ 3.3 kg/t
Caustic Flake
@ 350 g/t
Anionic PAM
@ 3 g/t
10 m³ / day 13 kg / day 33 kg / day 3.5 kg / day 30 g / day
50 m³ / day 65 kg / day 165 kg / day 17.5 kg / day 150 g / day
100 m³ / day 130 kg / day 330 kg / day 35 kg / day 300 g / day
500 m³ / day 650 kg / day 1650 kg / day 175 kg / day 1.5 kg / day
Prepare PAM as a dilute solution Anionic PAM powder is normally made up to a 0.1–0.2 % working solution and allowed to dissolve fully before dosing. Dosing dry powder gives poor results and blocks lines.
Treat these as a starting point These quantities are arithmetic conversions of one jar test. Use them to size a trial and plan storage, not as a guaranteed design dosage.
06 — Applications

Where this programme applies

The same logic transfers to other strongly coloured industrial effluents. The chemistry is the same; the dosage and the decolorant grade change with the water.

Textile dyeing & printing
Dye & pigment manufacturing
Denim & garment washing
Ink and coating production
Leather & tanning
Paper mill & recycled pulp
07 — FAQ

Questions we are asked most

Why is the dosage measured in kg/t rather than ppm?

Because the colour load is high. 1.3 kg/t is 1,300 ppm — roughly an order of magnitude above what a lightly tinted rinse water needs. Dark, concentrated liquors genuinely consume reagent in proportion to the colour they carry.

Can I skip the PAC and just use more decolorant?

It is the more expensive way to a worse result. Past the point of charge neutralisation, extra decolorant adds cost and sludge without adding clarity. PAC does a different job — building floc structure and sweeping suspended solids.

What if I skip the pH correction?

The polymer underperforms and you compensate with a larger dose. The caustic step costs 350 g/t; correcting for a bad pH costs considerably more in polymer.

Why is the treated water still slightly yellow?

Coagulation removes colour bodies that can be made particulate. Some small, highly soluble molecules stay dissolved and no amount of extra coagulant will capture them. Removing that residue requires a polishing step — activated carbon adsorption, an advanced oxidation stage, or membrane filtration.

Will this reduce COD as well?

Removing colour bodies as a solid phase removes the organics they represent, so a COD reduction normally comes with it. The magnitude depends on your water — it was not quantified in this particular test.

Can you run this test on my sample?

Yes. Send a sample with your target discharge parameters and we will run the same bench-scale procedure and report the dosage.

Free Laboratory Service

Send us your wastewater — we will run the jar test

Tell us your industry, daily flow and target discharge standard. Our laboratory will run a bench-scale trial on your own sample and report the exact chemical and dosage.

Products referenced in this case

Product Role in This Case Dosage
Water Decoloring Agent Charge neutralisation of dissolved colour bodies 1.3 kg/t
Poly Aluminium Chloride (PAC) Coagulation and micro-floc formation 3.3 kg/t
Caustic Soda Flake pH correction to the reaction window 350 g/t
Anionic Polyacrylamide (APAM) Floc bridging and rapid settling 3 g/t
The results described in this document were obtained from a bench-scale jar test on a single customer sample under laboratory conditions. Actual performance depends on the characteristics of each effluent. We recommend a jar test on your own wastewater before finalising a dosing programme.