request to quote
Leave Your Message

Shampoo Wastewater Decolorization: A Jar Test with Water Decoloring Agent, PAC and Anionic PAM

2026-09-10

Colored wastewater from shampoo production requires treatment conditions suited to the actual sample. A laboratory jar test provides a practical starting point for evaluating chemical selection and the treatment sequence before considering a larger-scale trial.

In this Bluwat Chemicals case study, a shampoo wastewater sample was treated using 08A decoloring agent, polyaluminium chloride (PAC), alkali and Anionic Polyacrylamide (PAM). The experiment focused on decolorization and floc formation through a four-step chemical treatment process.

Case Overview

Wastewater type: Shampoo wastewater
Test type: Laboratory jar test
Treatment focus: Decolorization, coagulation and flocculation
Treatment sequence: 08A decoloring agent → PAC → alkali adjustment to pH 7 → anionic PAM

The recorded dosages were 5,000 ppm for 08A decoloring agent and 1,000 ppm for PAC. Anionic PAM was added for flocculation, but its dosage was not recorded in the supplied test information.

shampoo wastewater treatment process(1).png

Step 1: Adding 08A Decoloring Agent

The first step was to add 08A decoloring agent at 5,000 ppm.

This stage targeted the color-related treatment requirement of the shampoo wastewater sample. During evaluation, the sample’s response after mixing should be documented to distinguish the effect of this initial addition from the changes produced by later treatment steps.

The recorded dosage applies to this particular experiment. Other shampoo wastewater samples require their own dosage screening.

Step 2: Adding PAC

PAC was then added at 1,000 ppm as the coagulation step.

This addition followed the decoloring agent in the tested sequence. Evaluating the sample after both additions helps establish how the combined treatment prepares the wastewater for the subsequent flocculation stage.

Step 3: Adjusting the pH to 7

Alkali was added after PAC to bring the measured pH to 7.

The test therefore used pH 7 as the condition immediately before adding anionic PAM. The amount of alkali was determined by the required pH adjustment; no fixed alkali dosage was supplied.

For a repeat test, the pH should be measured after the preceding chemical additions rather than assumed from the untreated wastewater.

Step 4: Adding Anionic PAM

Anionic PAM was added to promote floc formation.

This was the final chemical addition in the recorded procedure. The video can be used to document the flocculation stage, while a complete performance assessment would also examine the separated water and the behavior of the resulting solids.

What the Test Documents

This case establishes a specific treatment sequence and the recorded dosages of the two main Treatment Chemicals for one shampoo wastewater sample.

Numerical color removal, COD removal, turbidity reduction and discharge compliance were not reported. The case should therefore be interpreted as a laboratory treatment demonstration, with analytical testing needed to quantify performance.

Next Steps for Treatment Evaluation

A follow-up study can compare several dosages around the tested conditions and assess the resulting water quality, solids separation and chemical consumption.

Before full-scale use, the selected conditions should also be checked against representative wastewater samples and the plant’s actual treatment equipment.

Frequently Asked Questions

What chemicals were used in this shampoo wastewater test?

The sequence used 08A decoloring agent, PAC, alkali to adjust the pH to 7, and anionic PAM for flocculation.

What were the recorded chemical dosages?

The test used 5,000 ppm of 08A decoloring agent and 1,000 ppm of PAC. The anionic PAM dosage was not specified.

Can these dosages be applied directly to another plant?

They should be treated as sample-specific test conditions. Chemical selection and dosage need to be evaluated using the actual wastewater.

Discuss Your Shampoo Wastewater Treatment Needs

Bluwat Chemicals manufactures and supplies water treatment chemicals for industrial applications. Share your wastewater characteristics, current treatment process and treatment objectives with our team to discuss suitable products and sample testing.