request to quote
Leave Your Message
Reverse Emulsifier for Oily Wastewater | Bluwat Chemicals
Demulsifier
Products Categories
Featured Products

Reverse Emulsifier for Oily Wastewater | Bluwat Chemicals

Bluwat Reverse Emulsifier is an orange-yellow cationic polymer liquid designed to destabilize emulsified oil in industrial wastewater. It can be evaluated alone or with PAC and PAM through a sample-specific jar test.

    BLUWAT CHEMICALS · INDUSTRIAL WASTEWATER TREATMENT

    Reverse Emulsifier for Oily Wastewater Treatment

    At a glance: Bluwat Reverse Emulsifier is a cationic polymer liquid used to destabilize emulsified oil in industrial wastewater and support oil–water separation. It is relevant to oilfield produced water, machining wastewater and other oily effluents. A jar test is needed to confirm dosage, pH and the separation process for each wastewater sample.

    Typical appearance: orange-yellow liquid  |  Solids: ≥40%  |  Product pH: 2–4

    What Is Bluwat Reverse Emulsifier?

    This water-miscible cationic polymer treatment agent is intended for wastewater containing stable oil-in-water (O/W) emulsions, where small oil droplets remain dispersed in the water phase. By destabilizing the emulsion, it helps dispersed oil and suspended matter aggregate so they can be separated in the downstream treatment process. The result depends on the composition of the wastewater and the operating conditions.

    The product can be tested as a single treatment agent or as the first chemical step in a sequence with polyaluminium chloride (PAC) and polyacrylamide (PAM). PAC may assist coagulation, while PAM may improve subsequent floc formation and separation. The combined process should be selected by jar testing.

    Product scope: This page focuses on removing emulsified oil from the water phase. Breaking a water-in-oil (W/O) emulsion to dehydrate crude oil is a different application and requires a separate suitability test.
    Bluwat Reverse Emulsifier in its actual plastic drum packaging for industrial oily wastewater treatment

    Image placeholder: use a real photo of the product and packaging.

    Typical Wastewater Applications

    Oilfield produced water: Evaluate emulsion breaking and subsequent oil–water separation, including wastewater containing polymers from petroleum extraction.

    Machining and metalworking: Treat emulsified cutting fluid wastewater and oily rinse water from metal manufacturing.

    Steel and coking plants: Evaluate treatment of oily or emulsified wastewater from relevant production streams.

    Leather and fur processing: Evaluate separation of animal or vegetable oils in wastewater.

    Chemical manufacturing: Screen oily, high-strength industrial wastewater where an emulsion-breaking step is needed before further treatment.

    Application suitability depends on the emulsion, surfactants, salinity, pH and other constituents. Share a representative sample or water analysis for product selection.

    Product Specifications

    Appearance
    Orange-yellow liquid
    Solid content
    ≥40%
    Product pH
    2–4
    Packaging
    25 kg or 200 kg plastic drums; other options on request

    The pH value above describes the supplied product, not the wastewater treatment pH. Request the current TDS, SDS and batch COA for procurement and handling details.

    How to Use the Reverse Emulsifier

    1. Take a representative sample. Record the initial pH and observe how the oil is dispersed. Where available, measure the parameters needed for your treatment objective, such as oil and grease.
    2. Add the reverse emulsifier. Dose it directly or after dilution at a rapid mixing point so it disperses evenly. Screen several dosages in a jar test. The source product sheet gives 50–1000 ppm as a general starting range; the correct dose must be established for the actual wastewater.
    3. Assess pH and coagulation. The source sheet gives pH 5–12 as a general application range and notes strong effects around pH 9 in some conditions. If PAC is used, add it after the demulsifier, then check and adjust the pH for the specific treatment process.
    4. Add PAM where needed. After pH adjustment, add a suitably selected PAM solution to form separable flocs. Use gentle mixing after PAM addition, then allow settling or use the site's available separation equipment.
    5. Compare the results. Check phase separation, supernatant clarity, residual oil and sludge behavior. Adjust dosage and sequence based on measured results, not appearance alone.

    Example sequence for screening: Reverse emulsifier → PAC, if required → pH adjustment → PAM, if required → separation. This is a starting workflow, not a fixed process prescription.

    Actual Bluwat jar test showing stages of oilfield wastewater demulsification and flocculation

    Image placeholder: insert an actual jar test photo and update the alt text to describe what the photo shows.

    Packaging, Storage and Handling

    The product is supplied in 25 kg and 200 kg plastic drums; other packaging can be discussed. Store it in a cool place. The source product sheet states a one-year shelf life; confirm the period and storage conditions on the current batch documentation.

    Avoid direct contact with skin and eyes. If contact occurs, rinse promptly with plenty of water. Follow the current safety data sheet for complete protective equipment, first-aid and handling instructions.

    Frequently Asked Questions

    What is a reverse emulsifier used for?

    It is used to destabilize emulsified oil in wastewater so oil and water can be separated more effectively in a suitable treatment process.

    What dosage should I use?

    The source product sheet lists about 50–1000 ppm as a general reference range. Test your own wastewater at several doses and confirm performance and operating cost before setting a plant dose.

    What is the difference between product pH and operating pH?

    The liquid product has a pH of 2–4. The source sheet separately describes a wastewater application range of pH 5–12. The best operating pH must be determined for the actual sample.

    Can I use it with PAC and PAM?

    Yes, the product sheet recommends evaluating it with PAC and PAM. A typical trial adds the reverse emulsifier first, then PAC where required, adjusts pH, and adds PAM before separation. The need for each chemical should be confirmed by jar test.

    Can it treat every oilfield or cutting fluid wastewater?

    No single dose or treatment sequence is suitable for every wastewater. Emulsion chemistry and site conditions vary; use a representative sample to confirm suitability and performance.

    Which documents can buyers request?

    Ask Bluwat for the current technical data sheet (TDS), safety data sheet (SDS) and certificate of analysis (COA) for the relevant product and batch.

    Request a Sample or Jar Test Recommendation

    Tell Bluwat Chemicals the wastewater source, treatment flow rate, pH, oil and grease level, any surfactants or polymers present, and your separation target. Our team can recommend a screening approach and provide product documents for review.

    Contact: use your website's existing inquiry form or approved company contact link.